VARIOUS TESTS

Cold Shooting Test

Using the hunting cartridge at average pressure (max. 59(+/-3)Mpa) in chamber on safe position was waited 6 hours at -34 Celcius degrees.

7 pcs of cartridge was shot consequtively,Gun fired properly.

Result : Zero Error !

Hot Shooting Test

Using the hunting cartridge at average pressure (max. 59(+/-3)Mpa) in chamber on safe position was waited 6 hours at +55 Celcius degrees.

10 pcs of cartridge was shot consequtively,Gun fired properly.

Shooting Pressure Test

2 pcs of high pressure cartridge (118 +/-6 Mpa) was shot consequtively,

Gun fired properly.

Distrubition of Pellets

5 pcs. of Cartridge (36g.-no:7) at average pressure (max. 59 (+/-3)Mpa) was shot to 760mm dia.target from 35 meters distance.

Required Standarts : Avarage dispersion percentage must be 30-70% according to choke type.

Result : Distrubition percentage of pellets of 5 cartridges are 78%.

Drop Test

Gun is loaded one cartridge less then full capacity , one in chamber is ready to fire without gunpowder,gun is unsafe position gets dropped down ;

  • On barrel
  • On butt
  • On both sides

From 1 meter height onto a 2,5mm thickness rubber plate, layed down on concrete beton.

Required Standarts : Cartridge must not be fired,no firing pin sign on primer surface,no any impact sign or broken parts on gun.

Result : After drops ,gun gets shot 10 rounds , worked properly.

Zero Error !

Velocity Test

10 pcs of cartridge (59 +/-3 Mpa) were shot and measured velocity at barrel tip distance.

Required Standarts : Avarage velocity must be min. 345 m/s.

Result : Measured between 351-360 m/s.

Trigger Force Test

Required Standarts : Avarage must be 2500 g/f +/- 700

Result : Measured 2550 g/f